Standard Circuit House Minimum Number of Socket-Outlets How Many Are Needed?
Regulation 553.1.7 states Sufficient socket-outlets are required to be installed so that all equipment likely to be used can be supplied from a reasonably accessible socket-outlet, taking account of the length of flexible cable normally fitted to portable appliances and luminaires. Table H7 provides guidance on the number of socket-outlets that are likely to meet this requirement.
OW London Electrician and Home Automation Engineers Team
Standard Circuit House Socket-Outlets: How Many Are Needed?
Regulation 553.1.7 states:
"Sufficient socket-outlets are required to be installed so that all equipment likely to be used can be supplied from a reasonably accessible socket-outlet, taking account of the length of flexible cable normally fitted to portable appliances and luminaires. Table H7 provides guidance on the number of socket-outlets that are likely to meet this requirement."
- Important!
- Ref Guidance Note 1 Page 154
- The number of socket-outlets and their positioning should be such as to ensure compliance with Regulation 553.1.7, each socket-outlet of a twin or multiple socket-outlet unit being regarded as one socket-outlet.
In Scotland, Mandatory Standard 4.6 requires that every building must be designed and constructed in such a way that electric lighting points and socket-outlets are provided to ensure the health, safety, and convenience of occupants and visitors. The Building Standards Division of the Scottish Government make recommendations for the number of socket-outlets that should be installed in a domestic premises in Section 4.6.4 of the domestic technical handbook as follows:
- ▶ Kitchen – 6 (at least 3 above worktop height)
- ▶ Other habitable rooms – 4
- ▶ Plus at least 4 more throughout the property including at least one per circulation area per storey.
The socket-outlets may be either single or double.
H7 Table Minimum number of twin socket-outlets to be provided in homes (Source: Electrical Safety First and the Electrical Installation Forum.)
Room type | Smaller rooms (up to 12 m²) | Medium rooms (12–25 m²) | Larger rooms (more than 25 m²) |
---|---|---|---|
Main living room | 4 | 6 | 8 |
Dining room | 3 | 4 | 5 |
Single bedroom | 2 | 3 | 4 |
Double bedroom | 3 | 4 | 5 |
Bedsitting room | 4 | 5 | 6 |
Study | 4 | 5 | 6 |
Utility room | 3 | 4 | 5 |
Kitchen | 6 | 8 | 10 |
Garages | 2 | 3 | 4 |
Conservatory | 3 | 4 | 5 |
Hallways and landings | 1 | 2 | 3 |
Loft | 1 | 2 | 3 |
Location containing a bath or shower | see NOTE 3 | ||
Electric vehicle charging | see NOTE 4 |
Frequently Asked Questions
Q: How many socket-outlets should be installed in a standard UK kitchen?
A: According to Regulation 553.1.7, a standard UK kitchen should have at least 6 socket-outlets, with at least 3 of them above worktop height. This ensures that all equipment likely to be used can be supplied from a reasonably accessible socket-outlet.
Q: What is the recommended number of socket-outlets in a main living room?
A: Regulation 553.1.7, following the guidance in Table H7, recommends the following number of socket-outlets for a main living room:
- For smaller rooms (up to 12 m²): 4 socket-outlets
- For medium rooms (12–25 m²): 6 socket-outlets
- For larger rooms (more than 25 m²): 8 socket-outlets.
Q: How many socket-outlets should be installed in a double bedroom according to BS 7671?
A: As per Regulation 553.1.7 and Table H7, a double bedroom should have the following number of socket-outlets:
- For smaller rooms (up to 12 m²): 3 socket-outlets
- For medium rooms (12–25 m²): 4 socket-outlets
- For larger rooms (more than 25 m²): 5 socket-outlets.
Q: What is the minimum number of socket-outlets required in a utility room?
A: According to Regulation 553.1.7 and Table H7, a utility room should have the following number of socket-outlets:
- For smaller rooms (up to 12 m²): 3 socket-outlets
- For medium rooms (12–25 m²): 4 socket-outlets
- For larger rooms (more than 25 m²): 5 socket-outlets.
Q: Are there specific socket-outlet recommendations for garages?
A: Yes, Regulation 553.1.7 provides guidance in Table H7 for garages as well:
- For smaller garages (up to 12 m²): 2 socket-outlets
- For medium garages (12–25 m²): 3 socket-outlets
- For larger garages (more than 25 m²): 4 socket-outlets.